Sample: Underaged Sample 2 Ungroup Processes
Create Samples (1)
- Production method:
- { "name": "Other", "value": "Milling, turning, and grinding from prepared blanks." }
- Manufacturing Date:
- No value
- Supplier:
- Magnesium Elektron
- Manufacturer:
- Westmoreland Mechanical Testing and Research
Files
Fractographic Investigation of Ultrasonic Fatigue Specimens (1)
- Detector:
- { "name": "Secondary", "value": "secondary" }
- Working Distance:
- No value mm
- Magnification:
- No value
- Voltage:
- 15 kV
- Specimen/Stage Bias:
- No value V
- Stage:
- { "name": "Standard", "value": "standard" }
- Current:
- No value A
- Stage Tilt:
- No value degrees
Files
- Laboratory Air to Vacuum Fracture Surface Transition.tif
- Micro-Beach Mark Detail - T6 Condition.tif.tif
- Micro-Beach Marks - T6 Condition.tif
- Micro-Beach Marks - Underaged Condition.tif.tif
- Subsurface Facets - WE43.xlsx
- Subsurface Initiation - T6 Condition.tif
- Subsurface Initiation - Underaged Condition.tif
- Surface Facets - WE43.xlsx
- Surface Initiation - T5 Condition.tif
- Surface Initiation - T6 Condition.tif
- Surface Initiation - Underaged Condition.tif
- T5 Large View.tif See 1 more files......
Ultrasonic Fatigue (1)
- Resonating Frequency:
- 20 kHz
- Amplifiers (count):
- No value
- Stress Ratio:
- -1
- Power Control:
- No value
- Calibration Constant:
- No value
- Test Environment:
- Laboratory Air
- Max Stress:
- 85 MPa
- Test Temperature:
- 20 C