Sample: T5-4 (T5) Ungroup Processes
Last Updated: 4 years ago Owner: Jacob Adams ID: 7069
Create Samples (1)

Settings
Manufacturer:
Westmoreland Mechanical Testing and Research
Manufacturing Date:
No value
Production method:
{ "name": "Other", "value": "Milled, turned, and low-stress ground." }
Supplier:
Magnesium Elektron
Files
Fractographic Investigation of Ultrasonic Fatigue Specimens (1)

Settings
Detector:
{ "name": "Secondary", "value": "secondary" }
Working Distance:
No value mm
Magnification:
No value
Voltage:
15 kV
Specimen/Stage Bias:
No value V
Stage:
{ "name": "Standard", "value": "standard" }
Current:
No value A
Stage Tilt:
No value degrees
Files
Ultrasonic Fatigue (1)

Settings
Stress Ratio:
-1
Test Temperature:
20 C
Resonating Frequency:
20 kHz
Max Stress:
120 MPa
Test Environment:
Laboratory Air
Amplifiers (count):
No value
Power Control:
No value
Calibration Constant:
No value
Files