Sample: Varying Environment Sample 2 (Underaged) Ungroup Processes
Last Updated: 4 years ago Owner: Jacob Adams ID: 7092
Create Samples (1)

Settings
Manufacturing Date:
No value
Production method:
{ "name": "Other", "value": "Milling, turning, and grinding from prepared blanks." }
Supplier:
Magnesium Elektron
Manufacturer:
Westmoreland Mechanical Testing and Research
Files
Fractographic Investigation of Ultrasonic Fatigue Specimens (1)

Settings
Detector:
{ "name": "Secondary", "value": "secondary" }
Working Distance:
No value mm
Magnification:
No value
Voltage:
15 kV
Specimen/Stage Bias:
No value V
Stage:
{ "name": "Standard", "value": "standard" }
Current:
No value A
Stage Tilt:
No value degrees
Files
Ultrasonic Fatigue (1)

Settings
Test Environment:
Laboratory Air and Vacuum
Stress Ratio:
-1
Calibration Constant:
No value
Resonating Frequency:
20 kHz
Amplifiers (count):
No value
Power Control:
No value
Max Stress:
85 MPa
Test Temperature:
20 C
Files