Sample: AM70_5_AC Ungroup Processes
Last Updated: 4 years ago Owner: Erin Deda ID: 6778
AM70 5 beta (1)
Specimen/Stage Bias:
No value V
Voltage:
15 kV
Stage Tilt:
No value degrees
Working Distance:
10 mm
Magnification:
400
Stage:
{ "name": "Standard", "value": "standard" }
Current:
No value A
Detector:
{ "name": "Backscattered", "value": "backscattered" }
Files
AM70 5 EBSD (1)
Voltage:
30 kv
Magnification:
No value
Step Size:
0.5 microns
Acquisition Time:
No value
Scan Size Width:
No value
Working Distance:
20 mm
Sample Tilt:
70 degrees
Current:
No value
Files
Create Samples (1)
Production method:
{ "name": "Cast", "value": "cast" }
Manufacturing Date:
No value
Manufacturer:
MagTech
Supplier:
Ford Research and Innovation Center at MagTech Corporation
Heat Treatment (1)
Cooling Rate:
No value
Time:
2.25 h
Cooling Type:
{ "name": "Water Quench", "value": "water_quench" }
Temperature:
413 C
Tension (1)
Gage Length:
25 mm
Control Mode:
{ "name": "Displacement", "value": "displacement" }
Test Rate:
2 mm/min
Sample Geometry:
{ "name": "Rectangular", "value": "rectangular" }
Force Type:
{ "name": "Hydraulic", "value": "hydraulic" }
Temperature:
22 C
XRD (1)
Start Angle:
30 degrees
Rate:
0.5 degrees/minute
Step Size:
0.01 degrees
End Angle:
45 degrees
Type:
Rotating Anode
Files